PMII Certified


IICRC approved CE training
Approved CE Training

bbb

National Association of Mold Remediators and Inspectors NAMRI

National Non-profit Certifying Body for Mold Professionals

mold E&O insurance

Course Manager Contact Us Enroll/Order 

Professional Mold Inspection Institute Professional Mold Inspection Institute

PO Box 303 Madison, SD 57042Get Mold Certified Today!800-679-4381

USA CanadaHours 8am - 8pm CST, Mon-Fri

HYDRA Industrial Hydroxyl Generator
PCO and AOP Technology with Air Scrubber Function
  • HYDRA Industrial with 3 AOP Modes
  • Air Scrubber/Negative Air Functionality
  • Powerful, Germicidal UV Light
  • Airline Carry-on Luggage Compliant

$3,479.00

Free Shipping

Great for Mold Remediation and Water/Fire Restoration Companies
Hydroxyl Generator with Advanced Oxidation Processes, Treats Up To 6,000 sq ft

BoiE Hydra Hydroxyl GeneratorsDetails:
The ultimate, multipurpose hydroxyl generator for challenging restoration projects including mold and sewage remediation, water and fire damage restoration, and dust and odor control. Designed for restoration service companies large or small, the BoiE HYDRA Industrial combines the benefits of a portable HEPA air scrubber/negative air machine with the industry's most versatile hydroxyl generator with AOP functionality. A unique solution for indoor air purification or mold remediation projects.

In addition to PhotoCatalytic Oxidation (PCO) technology, the HYDRA Industrial offers three advanced oxidation process (AOP) modes that operate in the presence of UV light, to accelerate hydroxyl production. These options include low concentration Hydrogen Peroxide Vapor (HPV), low concentration UV Ozone (O3/UV), or a combination of both processes.

The HYDRA Industrial includes a unique hydrophilic system that generates and transfers water vapor or low concentration HPV to a direct injection manifold inside the machine that evenly distributes the vapor, accelerating and maximizing hydroxyl production. The unit can be used in PCO mode with occupants present, or in AOP mode with monitoring and appropriate PPE when workers are present.* Both modes are safe for plants and and sensitive materials.

How It Works:
Hydroxyls are highly-reactive molecules associated with water. They are nature's primary method of cleaning contaminants from the atmosphere using only sunlight and water vapor. Artificially-generated hydroxyls perform the same cleansing function on indoor air and cause no harm to people, pets, plants or materials.

Odors from flooding, mold spores, cigarette smoke, fire damage, sewage spills, off gassing, body odor and decomposition are all safely broken down by a hydroxyl generator until all that remains is carbon dioxide and water.

PCO Mode:
In PCO mode, the HYDRA Industrial harnesses the power of water, UV light and a catalyst to safely generate hydroxyls that neutralize odors, break down bacterial spores and pathogens, and leave nothing but fresh, clean air. PCO mode can be used with or without the included water vapor injection system, depending on site conditions. The resulting byproducts are harmless carbon dioxide and water.

PCO hydroxyl generation, originally developed by NASA, is ozone-free and safe to use indoors for continuous operation in unventilated spaces for as long as it takes to remove odors and break down contaminants.

Contaminated air is drawn through an odor-neutralizing pre-filter and a HEPA filter to trap most particulates. Next, the unit employs six germicidal (253-nm UVC) optics in a 2-layer crosshatch pattern along with 3 layers of nano-catalyst to produce hydroxyls that break down volatile organic compounds (VOCs) and other contaminants that pass through the unit's air flow. The machine's high static pressure centrifugal fan runs quietly, making it a good choice for occupied areas such as a client's home.

AOP Mode:
In AOP mode, the HYDRA Industrial activates a seventh optic that generates low concentration ozone, and/or hydrogen peroxide vapor as fuels to increase hydroxyl production. These two substances break down in the presence of germicidal UV light, providing the ingredients to saturate the air inside the machine with hydroxyls without requiring a catalyst. The resulting reactions can double the unit's efficacy, increase the overall coverage area or shorten the cleaning time.

Since a variable amount of unused ozone and/or hydrogen peroxide vapor will necessarily exit the machine, AOP mode requires an unoccupied area or proper worker protection, especially when there is little ventilation. Ozone and hydrogen peroxide will each break down naturally into oxygen and oxygen/water, respectively, after a few hours.

Both advanced oxidation processes are well-studied and are currently used in advanced water purification systems and medical sterilization systems. Below is a simplified example of the reactions that produce hydroxyls (•OH) using the HYDRA Industrial's AOP mode:

UV Light / Hydrogen Peroxide:
H2O2 + UV —› 2 •OH

UV Light / Ozone:
O3 + H2O + UV —› O2 + H2O2 followed by 2 O3 + H2O2 —› 2 •OH + 3 O2

UV Light / Hydrogen Peroxide + Ozone
Both reactions above occur with greater conversion of excess ozone into hydroxyls (•OH)

The Take Away:
The standard PCO mode is most beneficial when the machine can be run for longer periods of time, with or without occupants or workers present. The advanced oxidation process modes can increase the coverage area and decrease the cleaning time, provided that the job site is either unoccupied or is monitored for worker safety.* Both modes clean the air without causing damage to plants or sensitive materials.

The HYDRA Industrial includes BoiE's Ultrasonic Hydroxyl Accelerator accessory can turbocharge the air intake with moisture to maximize hydroxyl production in dry conditions. All BoiE products are designed by professionals for professionals to exceed, outlast and outperform the competition!


Hydroxyl Remediator Certification
(Limited Time Offer)
Your purchase includes BoiE's exclusive 32-hour, comprehensive Ozone and Hydroxyl Remediator certification course. Learn how to utilize hydroxl generation and properly apply ozone for odor removal, disinfection and restoration applications. Learn the protocols, how to identify and assess the source of odors, corrective measures and preparing treatment reports. Provides a path for starting a new business or expanding your current services. Course includes a helpful Online DVD with demonstration videos. You can enroll and simply use the course material as a reference if you don't need the certification.

Features:

  • Unbreakable, stackable rugged case
  • Padlock holes for added security
  • IPX7/MIL-STD810F and 512.4/IP6X Certifications
  • Wide track wheels and pull handle
  • Airline carry-on luggage compliant size
  • All-aluminum internal support frame for Hydroxyl Reactor
  • Reflective interior surface to increase hydroxyl production
  • HEPA Filter with built-In odor neutralizing particle pre-filter
  • Low-cost, common-sized, generic HEPA filter replacements
  • Air Scrubber / Negative Air functionality with or without optics on
  • Removable flanges to connect to containment area or ducting
  • Long-life 9,000 hour 253-nm UV-C (germicidal) optics with low power consumption
  • Lamps arranged in a 2 layer crosshatch for maximum air contact
  • TiO2 Catalyst Grid surrounding all lamps allows maximum hydroxyl generation and airflow
  • Quiet UL listed centrifugal blower with overload-protection
  • Marine-grade straight blade inlet receptacle fits extension cords
  • GFCI-protected electrical outlet and internal wiring
  • Marine-grade tin-plated copper wiring
  • Waterproof heat shrink electrical crimp connectors
  • Anti-oxidant compound applied to copper wire connections
  • Overload-protected transformers
  • BoiE warranty which exceeds the industry standard

Specifications

Type of Use:

Air purification treatments including allergens, smoke, mold and VOCs

Case Material:

Rugged polymer with stainless steel hinge pins

Case Type:

Crush-resistant, stackable, lockable, wheels and pull handle

Case Ratings:

IPX7/MIL-STD810F 512.4/IP6X Certifications

Orientation:

1-position, stand upright

Color:

Blue

Max Coverage:

6,000 sq ft with 10 ft ceilings

Filtration:

HEPA with built-in pre-filter

Air Scrubber:

Yes

Negative Air:

Yes

Fan:

365 CFM (max), shaded-pole centrifugal

Electrical Rating:

120V~60Hz 4.3 Amps

Mode 1:

PhotoCatalytic Oxidation (PCO)

Mode 2:

Advanced Oxidation Process (AOP)

Optics:

253-nm UV-C (germicidal) x6
185-nm UV-C (ozone-producing) x1

PCO Reactor:

BoiE 6-Optic 360-surround Reactor

Catalyst:

Permanent nano-anatase TiO2 (replaceable)

Power Connection:

Straight Blade Inlet Receptacle, Marine-grade

Accessory Outlet:

Yes, GFCI-protected

Power Switch:

Switch 1 (Air Scrubber): ON/OFF
Switch 2 (Hydroxyl Generator): PCO / OFF / AOP

Size:

24 x 16 x 10 inches

Weight:

28 lbs

Accessories:

20 ft. grounded power cord
Ultrasonic Direct Injection H2O/HPV Hydroxyl Accelerator ($299 value)


30-Day Money-Back Guarantee
The only mold inspection and remediation training with a satisfaction guarantee!

payments